Easy VIS methods for nanocolor water test kits

Easy VIS

Easy VIS validated methods for a majority of NANOCOLOR® test kits are available. To streamline your workflow, you will get predefined barcodes for each method, enabling the ScanStart™ feature.

Download Method Package
Easy UV methods for nanocolor water test kits

Easy UV

For Easy UV validated methods for a majority of NANOCOLOR® test kits are available. To streamline your workflow, you will get predefined barcodes for each method, enabling the ScanStart™ feature.

Download Method Package

How to Run Nanocolor Water Test Kits on EasyPlus UV/VIS Spectrophotometers

In this video, we explain how you can enable METTLER TOLEDO's EasyPlus UV/VIS spectrophotometers measuring Nanocolor® water test kits from Macherey-Nagel. This video will also demonstrate where the methods can be downloaded and how the handheld barcode reader can be used to facilitate your daily work.

What's Included in the Method Package?

ParameterTest Kit No.Total range
Aluminum918020.01–1.00 mg/L Al³⁺
Aluminum 079850980.02–0.70 mg/L Al³⁺
Ammonium918050.01–2.0 mg/L NH₄-N
Ammonium 109850040.2–8.0 mg/L NH₄-N
Ammonium 1009850084–80 mg/L NH₄-N
Ammonium 20098500630–160 mg/L NH₄-N
Ammonium 39850030.04–2.30 mg/L NH₄-N
Ammonium 509850051–40 mg/L NH₄-N
Bitter units9181722.0–80.0 BU
BOD₅-TT9858250.5–3000 mg/L O₂
Cadmium 29850140.05–2.00 mg/L Cd²⁺
Chlorine918160.02–10.0 mg/L Cl₂ 
Chlorine / Ozone 29850170.05–2.50 mg/L Cl₂
Chloride 509850210.50-50.0 mg/L Cl-
Chromate 59850240.1–4.0 mg/L CrO₄²⁻
COD 1500985029100–1500 mg/L O₂
COD 1500 Hg-free963029100–1500 mg/L O₂
COD 160 Hg-free96302615–160 mg/L O₂
COD 60 in saltwater9850206.0–60.0 mg/L O₂
COD 60009850125–60.0 g/L O₂
COD 15.0009850281000–15000 mg/L O₂
COD 16098502615–160 mg/L O₂
COD 30098503350–300 mg/L O₂
COD 409850272–40 mg/L O₂
COD 609850225–60 mg/L O₂
COD 60098503050–600 mg/L O₂
COD HR 150098503820–1500 mg/L O₂
COD LR 1509850363–150 mg/L O₂
Copper918530.01–10.0 mg/L Cu²⁺
Copper 59850530.10–7.00 mg/L Cu²⁺
Cyanide 089850310.02–0.80 mg/L CN⁻
Fluoride9181420.05–2.00 mg/L F⁻
Fluoride 29850400.1–2.0 mg/L F⁻
Formaldehyde 10985046 0.20–10.00 mg/L HCHO
Iron918360.01–15.0 mg/L Fe
Iron 39850370.10–3.00 mg/L Fe
Iron LR918128 0.005–5.00 mg/L Fe
Lead 59850090.10–5.00 mg/L Pb²⁺
Manganese 109850580.1–10.0 mg/L Mn
Nickel 49850710.10–7.00 mg/L Ni²⁺
Nitrate918650.1–30.0 mg/L NO₃-N
Nitrate Z918630.02–1.0 mg/L NO₃-N
Nitrate 2509850664–60 mg/L NO₃-N
Nitrate 509850640.3–22.0 mg/L NO₃-N
Nitrate 89850650.30–8.00 mg/L NO₃-N
Nitrite918670.002–0.30 mg/L NO₂-N
Nitrite 29850680.003–0.460 mg/L NO₂-N
Nitrite 49850690.1–4.0 mg/L NO₂-N
ortho- and total-Phosphate 19850760.05–1.50 mg/L P
ortho- and total-Phosphate 159850800.30–15.00 mg/L P
ortho- and total-Phosphate 459850555.0–50.0 mg/L P
ortho- and total-Phosphate 59850810.20–5.00 mg/L P
ortho- and total-Phosphate 5098507910.0–50.0 mg/L P
ortho- and total-Phosphate LR 19850950.05–0.50 mg/L P
ortho-Phosphate918770.04–6.5 mg/L PO₄-P
Oxygen 129850820.5–12.0 mg/L O₂
Phenol918750.01–7.0 mg/L Phenol
Phenolic index 59850740.2–5.0 mg/L Phenol
Potassium 509850452–50 mg/L K⁺
Residual Hardness 19850840.40–17.80 mg/L CaCO₃
Sulfate HR 1000985063200–1000 mg/L SO₄²⁻
Sulfate LR 20098506220–200 mg/L SO₄²⁻
Sulfate MR 40098506040-400 mg/L SO₄²⁻
Sulfide918880.01–3.0 mg/L S₂
Sulfide 39850730.05–3.00 mg/L S²⁻
Sulfite 1009850905–100 mg/L SO₃²⁻
Tin 39850970.10–3.00 mg/L Sn
total Chromium 29850590.05–2.00 mg/L Cr
total Nitrogen TNb 229850830.5–22.0 mg/L N
total Nitrogen TNb 2209850885–220 mg/L N
total Nitrogen TNb 609850923–60 mg/L N
Vicinal diketones985010 0.015–0.600 mg/kg Diacetyl
Zinc918950.02–3.0 mg/L Zn²⁺
Zinc 49850960.10–4.00 mg/L Zn²⁺
Zinc 69850420.20-6.00 mg/L Zn²⁺
Zirconium 1009850015–100 mg/L Zr
UV5 Nanocolor Methods for Water Test Kits

UV5

We are also working on ready-to-use methods for the UV/VIS Excellence line and will announce their availability soon. 

EasyPlus UV/VIS Methods for Spectroquant Water Test Kits

EasyPlus UV/VIS

The EasyPlus UV/VIS spectrophotometer comes pre-installed with over 150 methods, all validated with Spectroquant® test kits. These predefined and validated methods ensure that you receive accurate and reliable measurement results every time.

Download Method Database
EasyPlus UV/VIS

The Easy Water Testing Guide details over 150 water testing methods using Spectroquant® test kits. This guide provides clear and precise analytical test procedures, ensuring accurate and reliable results for all your water testing needs.

How to Install the SQKitReader Accessory for Spectroquant Water Test Kits

Learn how to easily install the SQKit reader accessory for Spectroquant water test kits on your EasyPlus UV/VIS spectrophotometer from METTLER TOLEDO.

Simply mount the SQKitReader on the magnetic pogo pins of the EasyPlus UV/VIS spectrophotometer and fix it with the included screw. After the initialization, the Spectroquant button appears on the home screen, enabling over 150 water test methods.

How to Perform Water Testing with EasyPlus UV/VIS Spectrophotometers

In this video, you will learn how to easily perform water testing measurements with Spectroquant™ test kits on your EasyPlus UV/VIS Spectrophotometer by METTLER TOLEDO.

In this category, more than 150 predefined methods are available. Scanning the 2D barcode of a test kit with the SQKitReader™ accessory automatically starts the corresponding method.

What's Included in the Method Database?

ParameterTest Kit No.Total rangeMethod
Acid Capacity Cell Test to pH 4.3 (total alkalinity) 1017580.40–8.00 mmol/LIndicator reaction
Aluminium Cell Test1005940.02–0.50 mg/L AlChromazurole S
Aluminium Test1148250.020–1.20 mg/L AlChromazurole S
Ammonium Cell Test1147390.010–2.000 mg/L NH4-NIndophenol blue
Ammonium Cell Test1145580.20–8.00 mg/L NH4-NIndophenol blue
Ammonium Cell Test1145440.5–16.0 mg/L NH4-NIndophenol blue
Ammonium Cell Test1145594.0–80.0 mg/L NH4-NIndophenol blue
Ammonium Test1147520.010–3.00 mg/L NH4-NIndophenol blue
Ammonium Test1006832.0–75.0 mg/L NH4-NIndophenol blue
Ammonium Test1006835–150 mg/L NH4-NIndophenol blue
AOX Cell Test1006750.05–2.50 mg/L AOXOxidation to chloride
Arsenic Test1017470.001–0.100 mg/L AsAg-DDTC
BOD Cell Test1006870.5–3,000 mg/L BODModification of Winkler method
Boron Cell Test1008260.05–2.00 mg/L BAzomethine H
Boron Test1148390.050–0.800 mg/L BRosocyanine
Bromine Test1006050.020–10.00 mg/L Br2S-DPD
Cadmium Cell Test1148340.025–1.000 mg/L CdCadion derivate
Cadmium Test1017450.0020–0.500 mg/L CdCadion derivate
Calcium Cell Test10085810–250 mg/L CaPhthalein purple
Calcium Test1148155–160 mg/L CaGlyoxal-bis-hydroxyanil
Calcium Test sensitive1148151.0–15.0 mg/L CaGlyoxal-bis-hydroxyanil
Calcium Test1000490.20–4.00 mg/L CaPhthalein derivate
Chloride Cell Test1147305–125 mg/L ClIron (III)-thiocyanat
Chloride Test1148972.5–25.0 mg/L ClIron (III)-thiocyanat
Chloride Test11489710–250 mg/L ClIron (III)-thiocyanat
Chloride Cell Test1018040.5–15.0 mg/L ClIron (III)-thiocyanat
Chloride Test11018070.10–5.00 mg/L ClIron (III)-thiocyanat
Chlorine Cell Test (free chlorine)1005950.03–6.00 mg/L Cl2S-DPD
Chlorine Cell Test (free chlorine + total chlorine)1005970.03–6.00 mg/L Cl2S-DPD
Chlorine Test (free chlorine)1005980.010–6.00 mg/L Cl2S-DPD
Chlorine Test (free chlorine)1006020.010–6.00 mg/L Cl2S-DPD
Chlorine Test (free chlorine + total chlorine)1005990.010–6.00 mg/L Cl2S-DPD
Chlorine Test (free chlorine + total chlorine)100086 /100087/100088/1000890.03–6.00 mg/L Cl2DPD
Chlorine Test (free chlorine + total chlorine)100086/100087/1000880.010–1.000 mg/L Cl2DPD
Chlorine Dioxide Test1006080.020–10.00 mg/L ClO2S-DPD
Chromate Cell Test1145520.05–2.00 mg/L CrDiphenylcarbazide
Chromate Cell Test (total chromium)1145520.05–2.00 mg/L CrPeroxodisulfate oxidation / Diphenylcarbazide
Chromate Test1147580.010–3.00 mg/L CrDiphenylcarbazide
Cobalt Cell Test1172440.05–2.00 mg/L CoNitroso-R salt
COD Cell Test1145604.0–40.0 mg/L CODChromosulfuric acid oxidation/chromatedetermination 
COD Cell Test1017965.0–80.0 mg/L CODChromosulfuric acid oxidation/chromatedetermination 
COD Cell Test11454010–150 mg/L CODChromosulfuric acid oxidation/chromatedetermination 
COD Cell Test11489515–300 mg/L CODChromosulfuric acid oxidation/chromatedetermination 
COD Cell Test11469050–500 mg/L CODChromosulfuric acid oxidation/chromatedetermination 
COD Cell Test11454125–1,500 mg/L CODChromosulfuric acid oxidation/chromium (III) determination
COD Cell Test114691300–3,500 mg/L CODChromosulfuric acid oxidation/chromium (III) determination
COD Cell Test114555500–10,000 mg/L CODChromosulfuric acid oxidation/chromium (III) determination
COD Cell Test1017975,000–90,000 mg/L CODChromosulfuric acid oxidation/chromium (III) determination
COD Cell Test (Hg free)10977210–150 mg/L CODChromosulfuric acid oxidation/chromate determination 
COD Cell Test (Hg free)109773100–1,500 mg/L CODChromosulfuric acid oxidation/chromium (III) determination
COD Cell Test for seawater1170585.0–60.0 mg/L CODChloride depletion / chromosulfuric acid oxidation/chromate determination
COD Cell Test for seawater11705950–3,000 mg/L CODChloride depletion / chromosulfuric acid oxidation/chromium (III) determination
Copper Cell Test1145530.05–8.00 mg/L CuCuprizone
Copper Test1147670.02–6.00 mg/L CuCuprizone
Cyanide Cell Test (free cyanide)1025310.010–0.500 mg/L CNBarbituric acid + pyridinecarboxylic acid
Cyanide Cell Test (free cyanide)1145610.010–0.500 mg/L CNBarbituric acid + pyridinecarboxylic acid
Cyanide Cell Test (readily liberated cyanide)1145610.010–0.500 mg/L CNCitric acid / barbituric acid + pyridinecarboxylic acid
Cyanide Test (free cyanide)1097010.0020–0.500 mg/L CNBarbituric acid + pyridinecarboxylic acid
Cyanide Test (readily liberated cyanide)1097010.0020–0.500 mg/L CNCitric acid / barbituric acid + pyridinecarboxylic acid
Cyanuric Acid Test1192532–160 mg/L Cyan AcidTriazine derivative
Fluoride Cell Test1008090.10–1.80 mg/L FAlizarin complexone
Fluoride Cell Test sensitive1008090.025–0.500 mg/L FAlizarin complexone
Fluoride Cell Test1172430.10–2.50 mg/L FSPADNS (As free)
Fluoride Test1145980.10–2.00 mg/L FAlizarin complexone
Fluoride Test1145981.0–20.0 mg/L FAlizarin complexone
Fluoride Test1008220.02–2.00 mg/L FSPADNS
Fluoride Test1172360.02–2.00 mg/L FSPADNS (As free)
Formaldehyde Cell Test1145000.10–8.00 mg/L HCHOChromotropic acid
Formaldehyde Test1146780.02–8.00 mg/L HCHOChromotropic acid
Gold Test1148210.5–12.0 mg/L AuRhodamine B
Hydrazine Test1097110.005–2.00 mg/L N2H44-Dimethylaminobenzaldehyde
Hydrogen Peroxide Cell Test1147312.0–20.0 mg/L H2O2Titanyl sulfate
Hydrogen Peroxide Cell Test sensitive1147310.25–5.00 mg/L H2O2Titanyl sulfate
Hydrogen Peroxide Test1187890.015–6.00 mg/L H2O2Phenanthroline derivative
Iodine Test1006060.050–10.00 mg/L I2S-DPD
Iron Cell Test1145490.05–4.00 mg/L FeTriazine
Iron Cell Test1148961.0–50.0 mg/L Fe (Fe (II) and Fe (III))2,2’-Bipyridine
Iron Test1147610.005–5.00 mg/L FeTriazine
Iron Test100796

0.010–5.00 mg/L Fe

(Fe (II) and Fe (III))

1,10-Phenanthroline
Lead Cell Test1148330.10–5.00 mg/L PbPAR
Lead Test1097170.010–5.00 mg/L PbPAR
Magnesium Cell Test1008155.0–75.0 mg/L MgPhthalein purple
Manganese Cell Test1008160.10–5.00 mg/L MnFormaldoxime
Manganese Test1147700.010–10.00 mg/L MnFormaldoxime
Manganese Test1018460.005–2.00 mg/L MnPAN
Molybdenum Cell Test1008600.02–1.00 mg/L MoBrompyrogallol red
Molybdenum Test1192520.5–45.00 mg/L MoMercaptoacetic acid
Monochloramine Test1016320.050–10.00 mg/L Cl2Indophenol blue
Nickel Cell Test1145540.10–6.00 mg/L NiDimethylglyoxime
Nickel Test1147850.02–5.00 mg/L NiDimethylglyoxime
Nitrate Cell Test1145420.5–18.0 mg/L NO3-NNitrospectral
Nitrate Cell Test1145630.5–25.0 mg/L NO3-N2,6-Dimethylphenol
Nitrate Cell Test1147641.0–50.0 mg/L NO3-N2,6-Dimethylphenol
Nitrate Cell Test10061423–225 mg/L NO3-N2,6-Dimethylphenol
Nitrate Test1147730.20–20.0 mg/L NO3-NNitrospectral
Nitrate Test1097130.10–25.0 mg/L NO3-N2,6-Dimethylphenol
Nitrate Cell Test in seawater1145560.10–3.00 mg/L NO3-NResorcine
Nitrate Test in seawater1149420.2–17.0 mg/L NO3-NResorcine
Nitrate Test1018420.3–30.0 mg/L NO3-NReduction / Benzoic acid derivative
Nitrite Cell Test1145470.010–0.700 mg/L NO2-NGriess reaction
Nitrite Cell Test1006091.0–90.0 mg/L NO2-NIron (II)-ethylenediammonium sulfate
Nitrite Test1147760.002–1.00 mg/L NO2-NGriess reaction
Nitrogen (total) Cell Test1145370.5–15.0 mg/L NPeroxodisulfate oxidation / Nitrospectral
Nitrogen (total) Cell Test1006130.5–15.0 mg/L NPeroxodisulfate oxidation / 2,6-Dimethylphenol
Nitrogen (total) Cell Test11476310–150 mg/L NPeroxodisulfate oxidation / 2,6-Dimethylphenol
Oxygen Cell Test1146940.5–12.0 mg/L O2Modification of Winkler method
Oxygen Scavengers Test1192510.020–0.500 mg/L DEHAFerroZine®
Ozone Test1006070.010–4.00 mg/L O3S-DPD
pH Cell Test1017446.4–8.8Phenol red
Phenol Cell Test1145510.10–2.50 mg/L C6H5OHMBTH
Phenol Test1008560.025–5.00 mg/L C6H5OHAminoantipyrine
Phenol Test1008560.002–0.100 mg/L C6H5OHAminoantipyrine by extraction
Phosphate Cell Test1004740.05–5.00 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test1145430.05–5.00 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test (total phosphorus)1145430.05–5.00 mg/L PPeroxodisulfate oxidation/phosphormolybdenum blue
Phosphate Cell Test1004750.5–25.0 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test1147290.5–25.0 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test (total phosphorus)1147290.5–25.0 mg/L PPeroxodisulfate oxidation/phosphormolybdenum blue
Phosphate Cell Test1006163.0–100.0 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test1006733.0–100.0 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test (total phosphorus)1006733.0–100.0 mg/L PPeroxodisulfate oxidation/phosphormolybdenum blue
Phosphate Test1148480.005–5.00 mg/L PO4-PPhosphormolybdenum blue
Phosphate Test1007981.0–100.0 mg/L PO4-PPhosphormolybdenum blue
Phosphate Cell Test1145460.5–25.0 mg/L PO4-PVanadatomolybdate
Phosphate Test1148420.5–30.0 mg/L PO4-PVanadatomolybdate
Potassium Cell Test1145625.0–50.0 mg/L KKalignost®, turbidimetric
Potassium Cell Test10061530–300 mg/L KKalignost®, turbidimetric
Residual Hardness Cell Test1146830.50–5.00 mg/L CaPhthalein purple
Silicate (Silicic acid) Test1147940.11–10.70 mg/L SiO2Silicomolybdenum blue
Silicate (Silicic acid) Test1147940.011–1.600 mg/L SiO2Silicomolybdenum blue
Silicate (Silicic acid) Test1008571.1–107.0 mg/L SiO2Molybdatosilicate
Silicate (Silicic acid) Test10085711–1,070 mg/L SiO2Molybdatosilicate
Silver Test1148310.25–3.00 mg/L AgEosine / 1,10-Phenanthroline
Sodium Cell Test in nutrient solutions10088510–300 mg/L NaIndirectly as chloride
Sulfate Cell Test1025321.0–50.0 mg/L SO4Bariumsulfate, turbidimetric
Sulfate Cell Test1145485–250 mg/L SO4Bariumsulfate, turbidimetric
Sulfate Cell Test10061750–500 mg/L SO4Bariumsulfate, turbidimetric
Sulfate Cell Test114564100–1,000 mg/L SO4Bariumsulfate, turbidimetric
Sulfate Test11479125–300 mg/L SO4Tannin
Sulfate Test1018120.50–50.0 mg/L SO4Bariumsulfate, turbidimetric
Sulfate Test1025375–300 mg/L SO4Bariumsulfate, turbidimetric
Sulfide Test1147790.020–1.50 mg/L SDimethyl-p-phenylendiamin
Sulfite Cell Test1143941.0–20.0 mg/L SO3Ellman’s reagent
Sulfite Cell Test sensitive1143940.05–3.00 mg/L SO3Ellman’s reagent
Sulfite Test1017461.0–60.0 mg/L SO3Ellman’s reagent
Surfactants (anionic) Cell Test1025520.05–2.00 mg/L SDASMethylene blue
Surfactants (cationic) Cell Test1017640.05–1.50 mg/L k-TenDisulfine blue
Surfactants (nonionic) Cell Test1017870.10–7.50 mg/L n-TenTBPE
Tin Cell Test1146220.10–2.50 mg/L SnPyrocatechol violet
TOC Cell Test1148785.0–80.0 mg/L TOCPeroxodisulfate oxidation / Indicator
TOC Cell Test11487950–800 mg/L TOCPeroxodisulfate oxidation / Indicator
Total Hardness Cell Test1009615–215 mg/L CaPhthalein purple
Volatile Organic Acids Cell Test10174950–3,000 mg/L CH3COOHEsterification
Volatile Organic Acids Test10180950–3,000 mg/L CH3COOHEsterification
Zinc Cell Test1008610.025–1.000 mg/L ZnPAR
Zinc Cell Test1145660.20–5.00 mg/L ZnPAR
Zinc Test1148320.05–2.50 mg/L ZnCl-PAN
UV/VIS Excellence methods for spectroquant water test kits

UV5

Enhance your water testing workflow with UV/VIS Excellence Spectrophotometers and versatile automation options. Tailor your processes to meet your specific demands, whether it's sample size or sample throughput, ensuring optimal efficiency and accuracy.

Download Method Package
UV/VIS Excellence

Our comprehensive Water Testing Guide illustrates the procedures for preparing water samples and obtaining results. It also features predefined water application methods. Learn to conduct reliable, fast water testing using METTLER TOLEDO’s UV/VIS Excellence spectrophotometer and test kits. Download the Water Testing Guide.

How to Achieve Fast, Safe, and Accurate Water Testing with a UV/VIS Excellence Spectrophotometer

With built-in calibration curves, ready-to-use test kits, and step-by-step guidance on the interface, you can save time and costs while ensuring accurate results in seconds. Increase your lab productivity and safety with the option to automate your workflow and test high throughput samples. Additionally, enjoy the flexibility of configuring your testing workflow and calibration curves while benefiting from additional built-in applications, such as substance quantification and color measurements. The compact design and robustness of the instrument also allow for convenient transport, making it the ideal choice for any lab setting.

How to Test COD, Ammonium, Phosphate, Chlorine, and Hardness in Water

Quickly test COD, ammonium, phosphate, chlorine, and hardness in water with a UV/VIS Excellence spectrophotometer. These parameters normally have to be analyzed and monitored in drinking, processing, and wastewater. 

What's Included in the UV5 Method Package?

ParameterTest Kit No.Total rangeMETTLER TOLEDO Method ID
Aluminium Cell Test1005940.02–0.50 mg/L AlM9930
Ammonium Cell Test1145440.5–16.0 mg/L NH4-N; 0.6–20.6 mg/L NH4+M9907
Ammonium Cell Test1145594.0–80.0 mg/L NH4-N; 5.2–103.0 mg/L NH4+M9919
Ammonium Cell Test1147390.010–2.000 mg/L NH4-N; 0.01–2.58 mg/L NH4+M9908
Ammonium Cell Test1145580.20–8.00 mg/L NH4-N; 0.26–10.30 mg/L NH4+M9921
Ammonium Test1147520.010–3.00 mg/L NH4-NM9937
Cadmium Test1017450.002–0.500 mg/L CdM9934
Chlorine Cell Test1005970.03–6.00 mg/L Cl2M9909
Chromate Test1147580.010–3.00 mg/L Cr; 0.02–6.69 mg/L CrO4M9938
COD Cell Test11454010–150 mg/LM9901
COD Cell Test1145604.0–40.0 mg/LM9912
COD Cell Test11454125–1,500 mg/LM9911
COD Cell Test114555500–10,000 mg/LM9917
COD Cell Test11469050–500 mg/LM9922
COD Cell Test11489515–300 mg/LM9939
Copper Cell Test1145530.05–8.00 mg/L CuM9928
Cyanide Test1097010.002–0.500 mg/L CN−M9933
Iron Cell Test1145490.05–4.00 mg/L FeM9925
Lead Cell Test1148330.10–5.00 mg/L PbM9927A*
Lead Cell Test1148330.10–5.00 mg/L PbM9927B*
Manganese Cell Test1008160.10–5.00 mg/L MnM9926
Nitrate Cell Test1145420.5–18.0 mg/L NO3-N; 2.2–79.7 mg/L NO3M9905
Nitrate Cell Test1147641.0–50.0 mg/L NO3-N; 4–221 mg/L NO3M9914
Nitrate Cell Test1145630.5–25.0 mg/L NO3-N; 2.2–110.7 mg/L NO3M9906
Nitrate Cell Test10061423–225 mg/L NO3-N; 102–996 mg/L NO3M9929
Nitrite Cell Test114547

0.03–2.30 mg/L NO2

−; 0.010-0.700 mg/L NO2-N

M9910
Nitrite Cell Test1006091.0–90.0 mg/L NO2-N; 3.3–295.2 mg/L NO2M9931
Nitrogen (Total) Cell Test1145370.5–15.0 mg/L NM9913
Nitrogen (Total) Cell Test11476310–150 mg/L NM9902
Phenol Test1008560.002–5.00 mg/LM9932
Phosphate Cell Test114546

0.5–25.0 mg/L PO4-P; 1.5–76.7 mg/L PO4

3−; 1.1–57.3 mg/L P2O5

M9903
Phosphate Cell Test114729

0.5–25.0 mg/L PO4-P; 1.5–76.7 mg/L PO4

3−; 1.1–57.3 mg/L P2O5

M9904
Phosphate Cell Test114543

0.05–5.00 mg/L PO4-P; 0.2–15.3 mg/L PO4

3−; 0.11–11.46 mg/L P2O5

M9918
Potassium Cell Test1145625.0–50.0 mg/L KM9935
Silicate (Silicic Acid) Test1147940.011–10.70 mg/L SiO2; 0.005–5.00 mg/L SiM9923
Silicate (Silicic Acid) Test1018130.25–500.0 μg/L SiO2; 0.12–233.7 μg/L SiM9924
Sulfate Cell Test114548

5–250 mg/L SO4

2−

M9915
Sulfate Cell Test114564

100–1,000 mg/L SO4

2−

M9920
Total Hardness Cell Test100961

5–215 mg/L Ca; 0.7–30.1°d; 0.9–37.6°e; 1.2–53.7°f; 7–301 mg/L CaO;

12–537 mg/L CaCO3

M9916

*Method selection depends on which procedure (A or B) is implemented. Please refer to the procedure description on the instruction sheet of the test kit.

UV/VIS water testing

UV/Vis Water Testing

Discover the Role of UV/Vis Spectrophotometry in Achieving Accurate Water Quality Analysis

UV/VIS Excellence Spectrophotometer

UV/VIS Excellence Spectrophotometer

Compact, Fast, and Reliable

cuvette portfolio

UV/Vis Cuvettes for Spectrophotometers

Glass and Quartz Cuvettes

pH meter

pH Meter

Wide Range of pH and Conductivity Meters for Laboratory and Field Use

autotitrators

Titrators

A Complete Range of Titrators and Accessories That Cover Your Titration Applications