Thermal Analysis Instruments for Compositional Analysis

Compositional Analysis Instruments

Thermogravimetric Analysis for Complex Analysis

Thermogravimetric analysis (TGA) is a thermal analysis technique used to study the compositional analysis of materials by measuring the mass change of a sample as a function of temperature or time. TGA can be used to determine the thermal stability of a sample, identify the decomposition temperature, and analyze the composition of complex materials.

価格に関するお問い合わせ
View Results ()
Filter ()

比較に他の1つまたは2つの製品を追加します

サービスの紹介 – 測定要件や製品に合わせたサポート

国際熱測定連合(ICTAC)によると、熱分析とは、物質の温度を温度プログラムの制御下で変化させながら、物質の物理特性を時間の関数として測定する一連の手法です。

ダウンタイムの最小化
サポート ・ 修理
機器のパフォーマンス
メンテナンス・最適化
コンプライアンス
校正・品質管理
専門知識の提供
トレーニング・コンサルティング
Thermal Analysis eNewsletter

FAQs

What types of samples can be analyzed with thermogravimetric analysis (TGA) for compositional analysis?

TGA can be used to analyze a wide range of materials, including polymers, composites, minerals, pharmaceuticals, and food products, among others. Any material that undergoes thermal decomposition or reaction can be studied with TGA.

What information can be obtained from thermogravimetric analysis in terms of compositional analysis?

TGA can provide information about the amount and type of materials present in a sample, as well as their thermal stability, decomposition profile, and reaction kinetics. It can also be used to identify the presence of impurities or contaminants in a material.

How does TGA compare to other thermal analysis techniques for compositional analysis?

TGA is a versatile and widely used technique for compositional analysis, but it is not the only thermal analysis technique available. Other techniques, such as differential scanning calorimetry (DSC) and thermomechanical analysis (TMA), can provide complementary information about a sample's thermal behavior and mechanical properties.

Can thermogravimetric analysis be used for quantitative compositional analysis?

Yes, TGA can be used for quantitative compositional analysis by measuring the mass loss of a sample as a function of temperature and comparing it to a reference sample or calibration curve. This method can be used to determine the amount of each component present in a mixture or composite material.

Are there any limitations or challenges to thermogravimetric analysis for compositional analysis?

One limitation of TGA is that it cannot provide information about the specific chemical bonds or functional groups present in a sample. Additionally, the thermal stability and behavior of a sample can be affected by factors such as sample preparation, heating rate, and atmosphere, which can make interpretation of the data more challenging.