View Results (53)
53 النتائج
Filter (53)

Pipette Tips RC LTS 20µL L 1000A/1

Bulk tips, 20 μL max. volume, for Rainin 2, 10 and 20 μL pipettes with LTS™ LiteTouch™, low retention, 1000 tips in bags (RC-L10LR).

إظهار المواصفات بالكامل

Pipette Tips RC LTS 250µL L 1000A/1

Bulk tips, 250 μL max. volume, for Rainin pipettes with LTS™ LiteTouch™, low retention, 1000 tips in bags (RC-L250LR).

إظهار المواصفات بالكامل

Pipette Tips RC LTS 1000µL L 1000A/1

Bulk tips, 1000 μL max. volume, for Rainin pipettes with LTS™ LiteTouch™, low retention, 1000 tips in bags (RC-L1000LR).

إظهار المواصفات بالكامل

Pipette Tips LQR LTS 20µL LS 960/10

Racked tips, 20 μL max. volume, for Liquidator™ 96 bench-top pipettor with LTS™, low retention, pre-sterilized, 960 tips in 10 racks of 96 (LQR-20SLR).

إظهار المواصفات بالكامل

Pipette Tips LQR LTS 20µL FL 960/10

Racked tips, 20 μL max. volume, for Liquidator™ 96 bench-top pipettor with LTS™, low retention, pre-sterilized, filter, 960 tips in 10 racks of 96 (LQR-20FLR).

إظهار المواصفات بالكامل

Pipette Tips LQR LTS 200µL LS 960/10

Racked tips, 200 μL max. volume, for Liquidator™ 96 bench-top pipettor with LTS™, low retention, pre-sterilized, 960 tips in 10 racks of 96 (LQR-200SLR).

إظهار المواصفات بالكامل
أضف منتجًا أو منتجين آخرين للمقارنة
Unlock Service Excellence - Maximize Your Efficiency

Explore our Services - Tailored to Fit your Equipment

We support and service your measurement equipment through its entire life-cycle, from installation to preventive maintenance and calibration to equipment repair.

وقت التشغيل. الدعم والإصلاح

الأداء. الصيانة والتحسين

الخبرة. التدريب والمشورة

What is an oxygen transmitter?

Within a measurement system, an oxygen transmitter, or GPO transmitter, is the component that communicates to the user or higher level control system and translates sensor readings into displayed measurements. Transmitters are an integral part of in-line measurement systems used for industrial process control and monitoring. METTLER TOLEDO offers a comprehensive range of high-performance oxygen transmitters that are compatible with traditional analog sensors and digital sensors with Intelligent Sensor Management (ISM).

How does an oxygen transmitter work?

An oxygen transmitter measures the raw signal from an analog analytical sensor and converts it into a digital signal, so that the oxygen measurement can be shown on the transmitter display. Amperometric oxygen transmitters can be programmed for various functions to improve measurement functionality, to control a process or to collect data. The signal is then displayed, and an output signal can be transmitted as an analog signal or as a digital signal via a fieldbus providing easy integration of sensor diagnostics into a process control system.

Which sensors can be connected to an oxygen transmitter?

METTLER TOLEDO's range of gas-phase oxygen sensors which can be conneceted to these gas-phase oxygen transmitters includes:

  • InPro 6800G - Wide range analog amperometric gas-phase oxygen sensor.
  • InPro 6850iG - Wide range digital ISM amperometric gas-phase oxygen sensor.
  • InPro 6900G - Analog amperometric gas-phase oxygen sensor for low oxygen measurement applications.
  • InPro 6950iG - Digital ISM amperometric gas-phase oxygen sensor for low oxygen measurement applications, designed for trace measurement in brewing.

What ISM functionalities are available with oxygen transmitters?

Intelligent Sensor Management (ISM) diagnostics are provided by METTLER TOLEDO gas-phase oxygen transmitters when integrated with an InPro 6850iG or InPro 6950iG sensor. The predictive diagnostics inform you when maintenance or calibration of the sensor is required. These oxygen transmitters also enable Plug and Measure technology. This speeds up sensor replacement and commissioning by allowing an oxygen sensor to be calibrated away from the process and then quickly installed at the measurement location.