Conductivity Sensor | Conductivity Probe

Conductivity Sensors for Process and Pure Water Measurement

A conductivity sensor measures the ability of a solution to conduct an electrical current. It is the presence of ions in a solution that allow the solution to be conductive: the greater the concentration of ions, the greater the conductivity. METTLER TOLEDO in-line conductivity probes are designed for pure water monitoring, chemical processing and pharmaceutical manufacturing processes. These conductivity sensors offer accurate, reliable measurement to ensure process control and compliance.

Call for Quote
View Results (81)
81 Results
Filter (81)

導電率センサ InPro7001/225-VP

InPro 7001/225-VPは、非常に低いものから中程度の導電率水で高精度測定が行えるよう設計された2極式導電率センサです。.

Show full specs

導電率センサ InPro7002/2 TC-VP

InPro 7002/2 TC-VPは、衛生アプリケーションで精度の高い測定を実現するよう設計された2極式導電率センサです。.

Show full specs

導電率センサ InPro7002/DN50-VAR-VP

InPro 7002/DN50-VAR-VPは、衛生アプリケーションで精度の高い測定を実現するよう設計された2極式導電率センサです。.

Show full specs

導電率センサ InPro7108-VP/PEEK/C22

InPro 7108-VP/PEEK/C22は4極式テクノロジーを利用して、中から高程度の導電率水に測定範囲を拡張しています。.

Show full specs

導電率センサ InPro7108-25/40-VP

InPro 7108-25/40-VPは4極式テクノロジーを利用して、中から高程度の導電率水に測定範囲を拡張しています。.

Show full specs

導電率センサ InPro7108-25/40/C22-VP

InPro 7108-25/40/C22-VPは4極式テクノロジーを利用して、中から高程度の導電率水に測定範囲を拡張しています。.

Show full specs
Add 1 or 2 more products to compare
Unlock Service Excellence - Maximize Your Efficiency

Explore our Services - Tailored to Fit your needs

We support and service your instruments through its entire life-cycle, from installation to preventive maintenance and calibration to equipment repair.

Uptime. Support & Repair

Compliance. Calibration & Quality

Expertise. Training & Consulting

FAQs

What is a conductivity sensor and a conductivity probe?

A conductivity sensor, also known as a conductivity probe or an in-line conductivity electrode, is an analytical instrument that measures the ability of a solution to conduct an electrical current. It is the presence of ions in a solution that allow the solution to be conductive: the greater the concentration of ions, the greater the conductivity. In some applications the purity measurement is made as resistivity (the reciprocal of conductivity). 

How many types of conductivity sensors and conductivity probes are there?

There are three technology types of METTLER TOLEDO conductivity sensors and conductivity probes used for process conductivity measurement:

How do you calibrate a conductivity sensor and a conductivity probe?

A METTLER TOLEDO conductivity sensor and conductivity probe can be calibrated against a solution of known conductivity (much like calibrating a pH sensor against a solution of a known pH). Alternatively, an in-line conductivity probe that contains a range of very precise resistors that duplicate known conductivity measurements can be used.

When do you need to perform a conductivity sensor calibration or verification?

In general, the cell constant of the in-line conductivity electrode will not change; however, if the sensing elements are altered in some way (e.g. solid deposition or other fouling of the electrodes or insulator of the sensor, loss of electrode material through corrosion) the cell constant will change. METTLER TOLEDO conductivity sensors are factory calibrated and the cell constant is precisely determined. Therefore, calibration is typically not required while using the in-line conductivity sensor. However, it is recommended to verify the conductivity sensor or make calibration adjustment if necessary on an annual basis. The frequency of verification or calibration is very much dependent on the applications or on the plant standard operating procedure requirements.

Show more