DO Sensor InPro6860i/12/220/mA/HD

DO Sensor InPro6860i/12/220/mA/HD

Anti-Bubble Dissolved Oxygen Sensor

The InPro6860i/12/220/mA/HD is an optical dissolved oxygen sensor with a mechanically modified hydrophilic surface. Combined with its tilted design, it prevents bubble accumulation, creating a highly stable measurement signal.

Increased Yield and Product Quality
The angled tip and hydrophilic surface prevent bubble formation. This eliminates noise for improved production efficiency and process control.

For Digital & Analog Bioreactors
This anti-bubble DO sensor has digital (MODBUS, RS-485) and analog (mA) output signals for compatibility with benchtop bioreactors and transmitters.

Sterilizable and Autoclavable
The InPro6860i/12/220/mA/HD provides fast, precise oxygen measurement, even after repeated autoclaving and sterilization cycles up to 140° C.

Contactez-nous pour un devis

Caractéristiques

Spécifications - DO Sensor InPro6860i/12/220/mA/HD

Watch the video on the Anti-Bubble OptoCap

Features and Benefits
Stable, Reproducible Yields
Achieving consistent batches and product quality requires reliable oxygen measurement. The hydrophilic surface finish and tilted tip of the oxygen sensor prevent measurement interference from bubble accumulation that can effect yield and product quality.
 
Hygienic and Durable Design
Avoiding biofouling and ensure a stable signal with the PTFE coating of the OptoCap™ oxygen-sensing element. This ensures that the InPro6860i/12/220/mA/HD has the durability to withstand multiple autoclaving and standard CIP / SIP cycles.
 
Uncompromised Reliability
This optical DO sensor offers the benefits and predictive diagnostics of Intelligent Sensor Management. Achieve faster start up with Plug and Measure technology. Increased system availability is provided by maintaining a stock of pre-calibrated sensors.

Exceptional Performance
The 220mm InPro6860i/12/220/mA/HD reduces both handling time and running costs due to lower calibration and maintenance needs. This performance is achieved by an electrolyte-free, one-piece replacement part that is monitored by predictive diagnostics.
 

Documentation

Documentations commerciales

Sonde à oxygène optique intelligente Manipulation simplifiée – Performances exceptionnelles
L’oxygène dissous (O2 dissous) doit être mesuré en continu au cours des procédés de fermentation et de culture cellulaire. La sonde à oxygène Anti-Bub...

Manuals

Operating Instructions: Optical O₂ Simulator
METTLER TOLEDO optical O2 sensors are intended solely for inline measurement of the oxygen partial pressure, as described in this instruction manual.

White Papers

Réduction de la corrosion
Ce livre blanc propose un contenu éducatif et partage une expertise pratique sur la façon de réduire la corrosion dans l’industrie de la chimie. Il ex...

Témoignage

Étude de cas sur la réduction de la maintenance
Cette étude de cas décrit comment Ajinomoto avait besoin de sondes de pH et d'oxygène plus fiables, et de moins de maintenance, et s'est tourné vers M...
Un véritable succès: Le bout du tunnel pour Novozymes
Martin Falk est très satisfait des performances de la sonde InPro 6860i : « Le nouveau système est plus stable et plus robuste. Dans l’idéal, nous aim...

Accessoire

Consommable

Logiciel

More Information

Demandez un Devis
DO Sensor InPro6860i/12/220/mA/HD
FDA
USP Class VI