Vochtsensor GPro 500

Vochtsensor GPro 500

De GPro 500 Moisture TDL kan nagenoeg onderhoudsvrij en zonder drift worden gebruikt in droge opslagtoepassingen, door de meting van waterdamp op ppm-niveau, zodat uw activa worden beschermd tegen roest:

 

  • Procescontrole
  • Opslag van Cl2
  • Opslag van EDC
 
Bel ons voor een offerte

Specificaties

Specificaties - Vochtsensor GPro 500

Gemeten gas Moisture / water vapor
Effective path length Probes: 100, 200, 400 mm (3.94", 7.87", 15.75")<br />Wafer cell: 50, 80, 100 mm (1.96", 3.15", 3.94")<br><br>Extractive cell: 200, 400, 800, 1000mm, 10m
Lower Detection Limit 5 ppm-v, 1 ppm-v
Meetbereik 0-200,000 ppm (0-2%), 0-100,000 ppm (0-1%)
Nauwkeurigheid 2% of reading or 10 ppm, whichever is greater
Lineariteit Better than 1%
Resolutie 5 ppm-v, 1 ppm-v
Drift Negligible (<2% of measurement range between maintenance intervals)
Sampling rate 1 second
Response time (T90) H2O in N2 1% to 0% in <4 sec
Repeatability ±0,25% of reading or 50 ppm-v O2 (whichever is greater)
Process pressure range 0.8 bar - 3 bar (abs)/11.6 psi - 29 psi (abs), 0.8 bar - 5 bar (abs)/11.6 psi – 72.5 psi (abs)
Process temperature range 0-250 ºC(32-482 ºF) <br />Optional(for probe instalation) 0-600 ºC (0-1112 ºF) with additional thermal barrier

Kenmerken en voordelen:

Instelbare diode laserspectroscopie

  • Betrouwbare en bewezen technologie


Eenvoudige installatie

  • Dankzij het ontwerp van de elektrode en de aansluiting met één flens


Meting ter plaatse

  • De directe metingen in de gasstroom zijn snel en betrouwbaar


SpectraID technologie

  • Voor zeer betrouwbare O2-metingen


Lage gebruikskosten

  • Geen bemonsterings- of conditioneringsapparatuur. Een jaarlijkse verificatie en de periodieke reiniging van de optica is het enige benodigde onderhoud


Laag verbruik van zuiveringsstikstof

  • Lagere bedrijfskosten


Voorspellende ISM-diagnostiek

  • Continue controle van de kwaliteit van het optische traject om vast te stellen wanneer het gereinigd dient te worden

 

 

Documentatie

Brochure

Brochure over gasanalyse
Veiligheid, kwaliteit en productiviteit: de belangrijkste factoren voor uw bedrijf. De ontwikkeling van onze analyzers en elektroden is daarom zeer do...

Folder

Gas Analysis
In this free booklet we discuss the theory of absorption spectroscopy and how TDL analyzers are being employed in an increasing number of process and...
Complimentary eBooklet: Gas Applications for GPro 500 Analyzers
This eBooklet is intended as a convenient reference to a selection of the most common GPro 500 applications.

White papers

White Paper: TDLs for All Your Processes – Folded-Path Gas Analyzers
Our portfolio of folded-path tunable diode laser (TDL) gas analyzers now has a unique range of process adaptions. Combined, they have opened the door...
No More Purge Gas-New TDLs for Combustion Processes
This white paper explains how the new generation of TDLs not only offers exceptional fuel costs savings, but eliminates the need for process side purg...
Measurement of Oxygen Concentration
Gaseous oxygen measurement with amperometric sensors is the most direct and easiest solution for protection against oxidation and explosion.
Procesanalyse
pH/ORP (Redox) elektrodes, zuurstof, CO₂, ozon sensors, bioburden, totale hoeveelheid organische koolstof (TOC), gas, natrium- en silica-analysators,...
Measurement of Oxygen Concentration
Gaseous oxygen measurement with amperometric sensors is the most direct and easiest solution for protection against oxidation and explosion.
Procesanalyse
pH/ORP (Redox) elektrodes, zuurstof, CO₂, ozon sensors, bioburden, totale hoeveelheid organische koolstof (TOC), gas, natrium- en silica-analysators,...
Minimizing Inerting System Maintenance
This white paper explains how TDL O₂ sensor can minimize inerting system maintenance & how to integrate them into a DCS system for fully automated oxy...
Procesanalyse
pH/ORP (Redox) elektrodes, zuurstof, CO₂, ozon sensors, bioburden, totale hoeveelheid organische koolstof (TOC), gas, natrium- en silica-analysators,...

Gegevensbladen

Data Sheet: H₂O Analyzer GPro 500
The GPro 500 TDL moisture sensor is designed for the measurement of H2O levels for corrosion prevention. In situ installation can avoid risks of toxic...

Technische specificaties

Manuals

Safety Manual for TDLS GPro 500 - Tunable Diode Laser Spectrometer
This document contains information and safety instructions required to use the GPro 500 with direct analog output option in SIL environments.

Video

Gas Analyzer - Gas Sensor
These highly reliable gas analyzers are designed to provide fast response times for a variety of gases in industrial and chemical processes. Both tuna...

Accessoires

Verbruiksartikelen

Software

More Information

Ontvang uw offerte
Vochtsensor GPro 500
FDA
USP Class VI