Tiếng Việt

Transmitter M100 2H DR

High Performance with a Small Footprint.The M100 DR is a DIN rail mounted single-channel, 2-wire process transmitter that supports multiple parameters and HART communication. It is compatible with pH/ORP, pH/pNa, DO and conductivity sensors.

Low Installation Cost

M100 DR is an easy-to-commission 2-wire transmitter for installations where space is at a premium.

Predictive Maintenance

Access to ISM predictive diagnostic tools available over HART leads to reduced maintenance and increased process uptime.

Plug & Measure Operation

With iSense software, sensors can be calibrated via a PC or mobile device, then connected to the M100 without the need to recalibrate.

Material No.: 30127720

Gọi để được báo giá

Các chức năng

Small Footprint

The M100 DR is designed to be DIN rail mounted. It is suitable for 35 mm wide DIN rail systems, and gives you the functionality that you require for control, without a local display.

Integration & Control via HART

The transmitter configuration and integration of sensor diagnostics into asset management tools is possible thanks to the integrated HART protocol. This ensures maximum compatibility and easy integration.

Easy-to-Analyze Indicators

The M100 DR is outfitted with two LEDs to clearly indicate transmitter and sensor status, and to communicate alarms and warnings visually to on-site maintenance staff.

Thông số kỹ thuật

Các thông số - Transmitter M100 2H DR

(Các) tham số
pH

Dòng điện ra
Đầu vào Analog

1
Truyền Dữ Liệu
lPhê duyệt cho khu vực nguy hiểm
Không
Phê duyệt và Chứng nhận
Tuân thủ tiêu chuẩn CE
Chế độ có dây
Bộ cấp nguồn
Giao diện Người dùng
(Các) Công tắc Rơ-le
Thiết bị Điều khiển PID

1
Vật liệu hộp
PA-FR
Chỉ số Bảo vệ
IP20
Giao diện USB
Kích cỡ
Phương tiện truyền thông/ứng dụng chính
Các quy trình hóa học
Các quy trình công nghiệp khác
Dòng model
M125

Small Footprint
The M100 DR is designed to be DIN rail mounted. It is suitable for 35 mm wide DIN rail systems, and gives you the functionality that you require for control, without a local display.

Integration & Control via HART
The transmitter configuration and integration of sensor diagnostics into asset management tools is possible thanks to the integrated HART protocol. This ensures maximum compatibility and easy integration.

Easy-to-Analyze Indicators
The M100 DR is outfitted with two LEDs to clearly indicate transmitter and sensor status, and to communicate alarms and warnings visually to on-site maintenance staff.

Tài liệu liên quan

Bảng dữ liệu

Data Sheet for M100 DIN Rail Transmitter
DIN Rail transmitter, high performance and minimal space requirement.

Thông số kỹ thuật

Technical Data: M100 DR DIN Rail Transmitter for pH/ORP, pH/pNa, Oxygen and Conductivity
The M100 DR DIN rail transmitter is a 2-wire transmitter with HART® communication capability for analytical measurements. The M100 DR is a single-chan...

Manuals

Operating Instructions: DIN Rail Transmitter M100 DR
These operating instructions offer important notes on handling of the M100 DR transmitter of METTLER TOLEDO. A prerequisite for safe work is complianc...
Quick Setup Guide Transmitter M100
The M100 is a 2-wire head mount transmitter for analytical measurements with HART communication capabilities. The M100 is a single-channel, multi-para...

Bus Communication Info

Phụ kiện

Vật tư tiêu hao

Phần mềm

More Information

Nhận Báo giá
Transmitter M100 2H DR
Hazardous Area
FM Approved
FDA