Gas-phase oxygen transmitters (GPO transmitters) integrate with METTLER TOLEDO amperometric gas phase oxygen sensors to deliver the oxygen measurement value, system status and sensor diagnostics to a user or higher level control system.
Transmitter M800 Process 1-CH
The single-channel M800 Process is a multi-parameter transmitter that provides high-performance, reliable measurement with a convenient full-color touch screen and the ability to integrate with a wide range of ISM and analog sensors.
Transmitter M800 Process 2-CH
The two-channel M800 Process is a multi-parameter transmitter that provides high-performance, reliable measurement with a convenient full-color touch screen and the ability to integrate with a wide range of ISM sensors.
Transmitter M800 Process 4-CH
The four-channel M800 Process is a multi-parameter transmitter that provides high-performance, reliable measurement with a convenient full-color touch screen and the ability to integrate with a wide range of ISM sensors.
Transmitter M800 Process 1-CH SS
The single-channel M800 Process is a multi-parameter transmitter with a stainless steel enclosure that provides high-performance, reliable measurement and offers the ability to integrate with a wide range of ISM and analog sensors.
Transmitter M800 Process 2-CH SS
The two-channel M800 Process is a multi-parameter transmitter with a stainless steel enclosure that provides high-performance, reliable measurement and offers the ability to integrate with a wide range of ISM sensors.
Transmitter M800 Process 4-CH SS
The four-channel M800 Process is a multi-parameter transmitter with a stainless steel enclosure that provides high-performance, reliable measurement and offers the ability to integrate with a wide range of ISM sensors.
Within a measurement system, an oxygen transmitter, or GPO transmitter, is the component that communicates to the user or higher level control system and translates sensor readings into displayed measurements. Transmitters are an integral part of in-line measurement systems used for industrial process control and monitoring. METTLER TOLEDO offers a comprehensive range of high-performance oxygen transmitters that are compatible with traditional analog sensors and digital sensors with Intelligent Sensor Management (ISM).
An oxygen transmitter measures the raw signal from an analog analytical sensor and converts it into a digital signal, so that the oxygen measurement can be shown on the transmitter display. Amperometric oxygen transmitters can be programmed for various functions to improve measurement functionality, to control a process or to collect data. The signal is then displayed, and an output signal can be transmitted as an analog signal or as a digital signal via a fieldbus providing easy integration of sensor diagnostics into a process control system.
METTLER TOLEDO's range of gas-phase oxygen sensors which can be conneceted to these gas-phase oxygen transmitters includes:
Intelligent Sensor Management (ISM) diagnostics are provided by METTLER TOLEDO gas-phase oxygen transmitters when integrated with an InPro 6850iG or InPro 6950iG sensor. The predictive diagnostics inform you when maintenance or calibration of the sensor is required. These oxygen transmitters also enable Plug and Measure technology. This speeds up sensor replacement and commissioning by allowing an oxygen sensor to be calibrated away from the process and then quickly installed at the measurement location.