
Manage your online profile and customize your mt.com experience
Browse a custom portfolio, access quotes, and manage your installed devices on our extended digital platform.
In-Line Gas Phase O₂ Measurement
The InPro 6800G/12/220/Ka is designed to withstand harsh process conditions to provide precise, in-line, gas-phase oxygen measurement.
Longer Process Uptime, Faster Maintenance
The modular design of the InPro 6800G/12/220/Ka allows for easy membrane exchange. The sensor can be calibrated with air at the measuring point.
Improved Process Reliability
The InPro 6800G/12/220/Ka ensures accurate, dependable measurement for a wide range of chemical and pharmaceutical applications.
Material No.: 52206428
The InPro 6800G/12/220/Ka offers accurate measurement between 0.1% and 100% oxygen, making it suitable for challenging applications such as off-gas monitoring or inertization in aggressive processes.
To meet the requirements of your specific application, the InPro 6800G/12/220/Ka is 220 mm long for medium to long length installations. It uses a Kalrez® O-ring with 316L stainless steel wetted parts for broad application coverage.
The InPro 6800G/12/220/Ka uses an anode/cathode assembly with an AgCl free anode to reduce drift. The membrane body can be replaced quickly, typically in less than 2 minutes, and the sensor can be calibrated in air at the point of measurement.
Amperometric oxygen sensors allow for very fast monitoring of changes in oxygen levels. The rapid response of the InPro 6800G/12/220/Ka, 90% in less than 20 seconds, allows you to quickly react to unwanted oxygen increases.
Measurement Parameter | Gas-Phase Oxygen |
Measurement Technology | Amperometric Clark Electrode |
Measurement Range | 1 to 100% Vol.-% O2 |
Accuracy | ≤ ±[1% +0.1 Vol-%] |
Response Time | T90 ≤ 20s (nitrogen to 15 Vol-% O2 at 25 °C / 77 °F) |
Primary Media/Application | Chemical Processes Pharmaceutical/Life Science Production |
ISM (Digital) or Analog | Analog |
Cable Connector | VP7 |
Sensor Length | 220 mm |
Process Connection | Pg 13.5 |
Connector Design | Straight |
O-Ring Material | Kalrez® |
Sensor Diameter | 12 mm |
Surface Roughness of Wetted Parts | N5/Ra 16 (Ra=0.4mm/16min) |
Wetted Materials | 316L Stainless Steel |
Wetted membrane material | PTFE |
Model Family | InPro6800G |
Detection limit | 300 ppm |
Detection limit | 0.1 Vol.-% O3 |
Sensor signal in air at 25 °C (77 °F) | 50...110 nA |
Residual signal in oxygen free media | <0.1 % of signal in ambient air |
Temperature compensation | Automatic |
Measuring Temp. Range | 32 °F – 158 °F (0 °C – 70 °C) |
Operating Pressure (Bar) | 0.200 bar–9.000 bar |
Operating Pressure (PSI) | 2.9 to 130 psi absolute |
Mechanical Temp. Range | 23 °F – 250 °F (-5 °C – 140 °C) |
Design pressure (bar) | maximum 12 bar |
Design Pressure (PSI) | maximum 174 psi absolute |
Hazardous Area Approvals | ATEX: Ex ia IIC T6 / T5 / T4 / T3 Ga / Gb, Ex ia IIIC T69 °C / T81 °C / T109 °C / T161 °C Da / Db. FM: IS Cl. I, II, III, Div 1, GR ABCDEFG / T6 * |
Hygienic/Biocompatibility Approvals | EHEDG, FDA/USP Class VI |
Other certificates | METTLER TOLEDO Quality Certificate, Material certificate 3.1, N5/Ra 17 |
Mechanical Temperature Resistance (Celsius) | -5 °C – 121 °C |
Operating Range | 301 ppm - 100% O2 |
Connection | VP (IP 68) Pg 13.5 |
Measured Pressure Resistance | 0.2 bar – 9 bar |
Mechanical Temperature Resistance (Fahrenheit) | 23 °F – 250 °F |
Reliable in Harsh Processes The InPro 6800G/12/220/Ka offers accurate measurement between 0.1% and 100% oxygen, making it suitable for challenging applications such as off-gas monitoring or inertization in aggressive processes. |
Suited to Your Process Needs To meet the requirements of your specific application, the InPro 6800G/12/220/Ka is 220 mm long for medium to long length installations. It uses a Kalrez® O-ring with 316L stainless steel wetted parts a broad application coverage. |
Reduced Service Time and Fast Exchange The InPro 6800G/12/220/Ka uses an anode/cathode assembly with an AgCl free anode to reduce drift. The membrane body can be replaced quickly, typically in less than 2 minutes, and the sensor can be calibrated in air at the measurement point. |
Fast Response Time Ensures Safety Amperometric oxygen sensors allow for very fast monitoring of changes in oxygen levels. The rapid response of the InPro 6800G/12/220/Ka, 90% in less than 20 seconds, allows you to quickly react to unwanted oxygen increases. |
O2 Sen InPro6800G/12/220/1611311