Tunable Diode Laser for O₂ Measurement

The GPro® 500 oxygen gas analyzer is a unique tunable diode laser spectrometer designed for safety applications. It uses a folded-path laser beam design for simple installation and measurement.

Fast Response In Safety Applications
An oxygen gas analyzer for safety applications, the GPro 500 provides a fast response time in combustion control and inerting applications.

Low Maintenance and Operating Costs
This oxygen gas analyzer is designed to operate in situ without a maintenance-prone conditioning system, reducing the total cost of ownership.

Easy Installation
The GPro 500 is an alignment-free TDL gas analyzer, meaning that the typical challenges of TDL installation and alignment are significantly reduced.

Pokličite za ponudbo

Specifikacije

Specifikacije - Oxygen Gas Analyzer: GPro 500

Izmerjeni plin Oxygen
Nižja meja zaznavanja 100 ppm-v
Merilni razpon 0-100%
Natančnost 1% of reading or 100ppm O₂, whichever is greater
Linearity Better than 1%
Ločljivost <0…01% vol O₂ (100ppm-v)
Zamik Negligible (<2% of measurement range between maintenace intervals)
Stopnja vzorčenja 1 second
Odzivni čas (T90) O₂ in N₂ 21%>0% in <2 seconds
Ponavljanje ± 0.25% of reading or 0.05% O₂ (whichever is greater)
Tlačno območje pri postopku 0.8 bar - 5 bar (abs)/11.6 psi - 72.52 psi (abs)
Temperaturno območje pri postopku 0-250°C (23-482°F)&semi; Optional(for probe installation)<br> 0-600°C (0-1112°F) with additional thermal barrier
Dejanska dolžina poti 50mm - 10m, depending on adaption
Prilagoditev postopkov ali senzor Sensor

Features and Benefits


Meets Critical Application Needs
This oxygen gas analyzer is ideal for applications such as: flare safety control, combustion control, chlorination and oxychlorination, process control, ESP filter production, vent headers, inertization and vapor recovery.
Meets Critical Application Needs
Immediate, In Situ Measurement
The GPro 500 oxygen gas analyzer is installed in situ, so you get a quick response without the need to extract and condition a sample. This provides a fast response time so that you can make real-time reactions to out-of-spec conditions.
Immediate, In Situ Measurement
Designed for Challenging Installations
The GPro 500 is configurable, enabling the oxygen gas analyzer's measurement system to be paired with a variety of process adaptions to meet a wide range of installation requirements.
Designed for Challenging Installations
Predictive Diagnostics Ensure Long Life
This oxygen gas analyzer uses Intelligent Sensor Management (ISM®) technology to offer predictive diagnostics on analyzer condition, including informing you when cleaning of the optical path will be required.
Predictive Diagnostics Ensure Long Life

Dokumentacija

Brošure

Gas Analytics Brochure
Varnost, kakovost, storilnost: to je za vas najbolj pomembno. Zato tudi naš pristop k zasnovi analizatorjev in senzorjev temelji na preprostem izzivu...

Preglednica

Data Sheet: O2 Gas Analyzer GPro 500
The GPro® 500 oxygen gas analyzer is a unique tunable diode laser spectrometer designed for safety applications. It uses a folded-path laser beam desi...

Tehnične specifikacije

White Papers

Process Gas Analyzers – 5 Problems
This white paper looks at five issues around process gas analyzers and how tunable diode laser (TDL) spectrometers circumvent them.

Raziskave primerov

Analizator plina – senzor plina
Ti izjemno zanesljivi analizatorji plina so zasnovani za hitro odzivanje na številne pline v industrijskih in kemičnih procesih. Nastavljivi diodni la...
Procesna analitika
pH sonde, ORP Redox sonde, kisik, CO2, senzorji za ozon, analizatorji za biokontaminante, TOC, plin, natrij in silicijev dioksid, transmiterji

Application Notes

Procesna analitika
pH sonde, ORP Redox sonde, kisik, CO2, senzorji za ozon, analizatorji za biokontaminante, TOC, plin, natrij in silicijev dioksid, transmiterji

Programska oprema

Dodatki

Potrošni material

Programska oprema

More Information

Zahtevajte ponudbo
Oxygen Gas Analyzer: GPro 500
FDA
USP Class VI