Accurate, Reliable Sodium Monitoring
Combination sodium and pH electrode system confirms reagent addition for reliable operation, minimizes reagent consumption, and reduces maintenance.
Configurable, Automated Calibration
Unattended, automated calibration ensures the accurate measurement of sodium in your water system and detects breakthroughs right when they occur.
Partial Enclosure for Easy Access
Convenient access to flow controls and visibility of reagent and calibration standard levels for easy verification.
Material No.: 58042001
Accurate, Reliable Sodium Monitoring
Combination sodium and pH electrode system confirms reagent addition for reliable operation, minimizes reagent consumption, and reduces maintenance.
Configurable, Automated Calibration
Unattended, automated calibration ensures the accurate measurement of sodium in your water system and detects breakthroughs right when they occur.
Fully Enclosed for Dirty Environments
Especially suitable for plant floor locations in coal-fired power plants and where a locking door is needed.
Sodium Measurement Range | 0.001 - 100,000 ppb or equivalent ppm, autoranging |
Sodium Measurement Accuracy | ±10% of reading or ± 0.05 ppb whichever is greater |
Response Time | 90% at 5 minutes |
Sample pH | 2.5-12 |
Update Rate | Once per second |
Reagent Consumption | Diisopropylamine (DIPA), approximately 1 L per 3 months more at higher temperatures and for cation exchange samples |
Sample Flow rate | >40 mL/min (>20 mL/min for cation exchange samples), excess to drain |
Sample Temperature | 5-50°C (41-122°F) |
Sample Pressure | 0.3-7 bar (5-100 psig) |
Grab Sample Measurement | Included |
Power Supply | 100-240 VAC, 50-60 Hz, 25 W, on power loss all settings are retained without batteries |
Dimensions (HxWxD) | 35.4"x17.7"x7.5" (900x450x190 mm) |
Weight | 27 kg (60 lbs) |
Ambient Operating Temperature | 10-45°C (50-113°F) |
Humidity | 10-90% non-condensing |
Ratings/Approvals | CE / cULus |
Process Connection | Sample Inlet: 1/4" or 6 mm OD tube SS compressin fitting Drain Hose: 19x25.4 mm (3/4 x 1") 2 m (6 ft) length included |
Operator Interface | 4-line backlit LCD, 5 tactile keys simultaneous display of sodium, conditioned pH, auto-cal status (temperature optional) |
Analog Output | For sodium, conditioned pH, temperature four powered 0/4-20 mA, 22mA alarm, 500 ohm max load, not for use with externally powered circuit |
Analog Output Scaling | Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging |
Measurement Parameter | Sodium |
Electrode Conditioning | Part of auto-cal sequence |
Relay Contacts | 3A resistive freely assignable to setpoints for sodium, pH, temperature other relays used for auto-cal Two unpowered, SPDT, 250VAC/30VDC |
Sodium Calibration | Automatic, unattended 3-point known addition |
Calibration | Automatic |
Analog Output Accuracy | ±0.05 mA |
Model Family | 2300Na |
EnclosureType | Partial |
Built-in sequencer | No |