The GPro 500 carbon monoxide (CO) gas analyzer is a unique tunable diode laser spectrometer designed for direct measurement of CO in combustion control applications. It uses a folded-path laser beam design for simple installation and CO measurement.
Top Performance in CO Measurement
A CO analyzer for challenging applications, the GPro 500 provides a reliable measurement in process control and combustion applications.
Low Maintenance and Operating Costs
This CO gas analyzer is designed to operate in situ without a maintenance-prone conditioning system, reducing the total cost of ownership.
Easy Installation
The GPro 500 is an alignment-free TDL gas analyzer, meaning that the typical challenges of TDL installation and alignment are significantly reduced.
This CO gas analyzer is ideal for process control in combustion applications. The GPro 500 CO gas analyzer is optimal for measurement in fired heaters, incinerators, and ESP filters. These TDL gas analyzers offer precise, reliable, and fast measurement.
The GPro 500 CO gas analyzer is installed in situ, so you get a quick response without the need to condition a sample. This offers a reliable and cost-effective alternative to technologies that require maintenance prone extraction and conditioning systems.
The GPro 500 is configurable, enabling the carbon monoxide gas analyzer's measurement system to be paired with a variety of process adaptions to meet a wide range of installation requirements.
This CO gas analyzer uses Intelligent Sensor Management (ISM) technology to offer predictive diagnostics on analyzer condition, including informing you when cleaning of the optical path will be required. Predictive Diagnostics Ensure Long Life
Gas Measured | Carbon monoxide |
Lower Detection Limit | 1 ppm-v |
Measurement range | 0-120,000 ppm (0-2%) |
Accuracy | 2% of reading or 1 ppm, whichever is greater |
Linearity | Better than 1% |
Resolution | 1 ppm-v |
Drift | Negligible (<2% of measurement range between maintenace intervals) |
Sampling rate | 1 second |
Response time (T90) | CO in N₂ 300 ppm-v to 0% in <4 seconds |
Repeatability | ±0.25% of reading or 5 ppm-v CO (whichever is greater) |
Process pressure range | 0.8 bar - 2 bar (abs)/11.6 psi - 29. psi (abs) |
Process temperature range | 0-250 °C (23-482 °F); optional (for probe installation) <br>0-600 °C (0-1112 °F) with additional thermal barrier |
Effective path length | 50 mm - 10 m, depending on adaption |
Process Adaption or Sensor | Sensor |
Carbon Monoxide Gas Analyzer: GPro 500