Control at Low PPB Oxygen Levels
The high-performance DO sensor meets all ultrapure water, low ppb-level measurement challenges in the power and microelectronics industries.
Rapid, Accurate Response
The accuracy of the DO sensor allows it to perform well at any level and provide rapid response to changes from one level to another.
Tailored to Your Processes
The sensor has been especially designed for power plant cycle chemistry monitoring of ultrapure water in semiconductor and pure water treatment systems.
Material No.: 52201067
Measurement Technology | Amperometric/Polarographic |
Operating Range | 0 ppb – 10,000 ppb |
Accuracy | ± 1% of reading or 1 ppb, whichever is greater ± 0.5 °C |
Flow Rate | 0.79 gal/h – 18.85 gal/h (50 mL/min – 1,000 mL/min) |
Measuring Temperature Range (Celsius) | 0°C – 60°C for temperature compensation can tolerate 100°C |
Measuring Temperature Range (Fahrenheit) | 32°F – 140°F for temperature compensation can tolerate 212°F |
Response Time | 98% in 90 seconds |
Preamp | Integral |
Intelligent Sensor Management (ISM®) | No |
Weight | 1 kg (2 lb) with flow housing |
Wetted Materials | Polyphenylene sulfide probe body Polyacetal flow housing PTFE membrane reinforced with stainless steel and silicone rubber, Viton® and silicone rubber o-rings |
Cable Connection | 1/4” NPT(M) |
Cable | N/A |
Material Number | 52201067 |
Sensor Length | 210 mm |
Model Family | UPW DO sensors |
ISM (Digital) or Analog | Analog |
Measurement Parameter | Oxygen |
Measured Pressure Resistance | 0 psig – 72 psig (0 bar – 5 bar) |
Primary Media/Application | Semiconductor Water Pharmaceutical Waters Power Plant Water/Steam |
Autoclavable/Sterilizable | No |
Fast Response with Long-term Stability
With a design that prevents stray oxygen from affecting the measurement signal, the analog high-performance DO probe delivers a very rapid downscale response that helps to ensure the power plant starts up successfully and produces water that is free of defects.
Long Life with Exceptional Durability
Combining high performance with a long service life, the analog high-performance DO sensor's gas-permeable, stainless steel, mesh-reinforced PTFE membrane ensures high dependability within demanding low-level ppb applications.
Simplified Sensor Maintenance
The maintenance of the in-line DO sensor is simple due to its drop-in modular design. Routine maintenance ensures a reliable sensor performance.
The DS AK9-RJ12 is a USB cable adaptor for connecting ISM 1-wire sensors to iSense software. This allows pH, DO and CO2 sensors to be evaluated, maintained and calibrated in the workshop or laboratory.
Diagnostics Away From the Transmitter
The iLink module allows you to access all of the diagnostics of your ISM sensors away from the process with iSense desktop software.
Application Profiling Drives Performance
Store application data on iSense and load directly into an ISM sensor. This allows sensors to learn from preceding sensors in the same process.
Easy Access to Paper Free Documentation
The iLink cable allows sensor calibration and adjustment protocols to be generated automatically in iSense and stored in a fully digital database.
Material No.: 52300383