Increased Yield and Product Quality
The angled tip and hydrophilic surface prevent bubble formation. This eliminates noise for improved production efficiency and process control.
For Digital & Analog Bioreactors
This anti-bubble DO sensor has digital (MODBUS, RS-485) and analog (mA) output signals for compatibility with benchtop bioreactors and transmitters.
Sterilizable and Autoclavable
The InPro 6860i/12/120/mA/HD provides fast, precise oxygen measurement, even after repeated autoclaving and sterilization cycles up to 140° C.
Material No.: 30449705
Achieving consistent batches and product quality requires reliable oxygen measurement. The hydrophilic surface finish and tilted tip of the oxygen sensor prevent measurement interference from bubble accumulation that can affect yield and product quality.
Avoiding biofouling and ensure a stable signal with the PTFE coating of the OptoCap™ oxygen-sensing element. This ensures that the InPro6860i/12/120/mA/HD has the durability to withstand multiple autoclaving and standard CIP / SIP cycles.
This optical DO sensor offers the benefits and predictive diagnostics of Intelligent Sensor Management. Achieve faster start up with Plug and Measure technology. Increased system availability is provided by maintaining a stock of pre-calibrated sensors.
The 120mm InPro6860i/12/120/mA/HD reduces both handling time and running costs due to lower calibration and maintenance needs. This performance is achieved by an electrolyte-free, one-piece replacement part that is monitored by predictive diagnostics.
Measurement Parameter | Oxygen |
Measurement Technology | Optical fluorescence quenching |
Accuracy | ± (1 % of the reading + 8 ppb) |
Response Time | T98 = < 90 s |
Primary Media/Application | Pharmaceutical/Life Science Production |
ISM (Digital) or Analog | ISM (Digital) |
Anti-Bubble Design | Yes |
Wetted Metallic Material | 316L stainless steel |
Surface Roughnes of Wetted Material | N5/Ra16 (Ra=0.4μm/16μin) |
Sensor Diameter | 12 mm |
O-Ring Material | EPDM |
Power | 25 V DC 0.1 A |
Process Connection | Pg 13.5 |
Sensor Length | 120 mm |
Wetted membrane material | PTFE |
Connector Design | Straight |
Model Family | InPro 6860i |
Autoclavable/Sterilizable | Yes |
CIP resistant | Yes |
Measuring Temp. Range | 41 °F – 140 °F (5 °C – 60 °C) |
Mechanical Temp. Range | -4 °F – 284 °F (-20 °C – 140 °C) |
Operating Pressure (Bar) | 0.2–6 Bar |
Operating Pressure (PSI) | 0–87 PSI |
Design Pressure | 87 psi (6 bar) |
Analog Integration | 4/20 mA HART active output |
Digital Integration | RS485 - ISM® and MODBUS RTU |
Cable Connector | VP6 / VP8 (analog / digital) |
Hygienic/Biocompatibility Approvals | FDA/USP Class 7 |
Hazardous Area Approvals | ATEX/IECEx: II 1/2G Ex ia/ib HC T6 Ga/Gb II1/2D Ex ia/ib nie T83 °C Da/Db |
Certificates & Approvals | Quality certificate, Material certificate 3.1, Surface finish certificate, ATEX/IECEx certificate, FDA/USP Class IV |
Measurement Range | 0...saturation |
Sterilizable/Autoclavable | Yes |
Watch the video on the Anti-Bubble OptoCap
Uncompromised Reliability
This optical DO sensor offers the benefits and predictive diagnostics of Intelligent Sensor Management. Achieve faster start up with Plug and Measure technology. Increased system availability is provided by maintaining a stock of pre-calibrated sensors.
Material No.: 30365367
Material No.: 30014134
Material No.: 30130631
DO Sensor InPro6860i/12/120/mA/HD