Analyzer 2301Na Panel Assy

Analyzer 2301Na Panel Assy

Simple, Dependable Operation.The 2301Na Sodium Analyzer delivers solid value with simple, early detection of trace sodium contamination. It is an ideal solution for staying under budget with in-line sodium monitoring in ultrapure water or steam cycle chemistry.

Measurement Dependability

A combination pH and reference electrode system confirms the pH of the incoming sample for accurate reagent addition and data measurements.

Open Panel Design Reduces Costs

The open panel design reduces costs in areas where additional protection is not required, allowing customers to easily meet budget constraints.

Maximum Uptime

Minimal maintenance requirements and reagent consumption plus the absence of KCl reduces operating costs and maximizes analyzer uptime.

Material No.: 58042003

Call for Quote

Features

Simple, Safe Operation

Simple flexibility with manual calibration and grab sampling capability, plus the option to use DIPA or ammonium hydroxide reagent.

Worldwide Local Support

With local offices staffed by trained sales and service personnel across the world, skilled technical help is always available. Rely on our experienced team of service technicians for dependable, efficient support.

Full Lifecycle Value

The 2301Na analyzer delivers measurement accuracy and reliability to exceed your expectations, not your budget. With long, 6-month maintenance intervals you can ensure analyzer uptime with less frequent etching, calibration and lower reagent consumption.

Complete Protection, Safe Operation

Long-lasting consumables, reagent flexibility, minimal maintenance requirements and a fully enclosed design provide maximum operator safety at all times.

Specifications

Specifications - Analyzer 2301Na Panel Assy

Sodium Measurement Range
0.01-100,000 ppb or equivalent ppm, auto-ranging
Sodium Measurement Accuracy
± 10% of reading ± 0.1 ppb, typical
using DIPA as reagent
± 10% of reading ± 1 ppb, typical
using ammonium hydroxide as reagent
Response Time
90% at 5 minutes
Sample pH
2.5-12
Update Rate
Once per second
Reagent Consumption
3-4 L per year DIPA, or 9-12 L per year ammonium hydroxide typical
more at higher temperatures and for cation exchange samples
Sample Flow rate
>40 mL/min (>20 mL/min for cation exchange samples), excess to drain
Sample Temperature
5-50°C (41-122°F)
Sample Pressure
0.3-7 bar (5-100 psig)
Grab Sample Measurement
Available option
Power Supply
100-240 VAC, 50-60 Hz, 25 W, on power loss all settings are retained without batteries
Dimensions (HxWxD)
851 x 400 x 165 mm (33.5" x 15.75" x 6.5")
Weight
4.5 kg (10 lbs)
Ambient Operating Temperature
5-50 °C (41-122 °F)
Humidity
10-90% non-condensing
Ratings/Approvals
CE, UL, IP65
Dimensions (HxWxD)
851 mm x 400 mm x 165 mm
Process Connection
Sample inlet: 6 mm or 1/4" OD tube SS compression fitting Drain hose: 19 x 25.4 mm (¾ x 1"), 2 m (6 ft) length included
Analog Output
22mA alarm, 500 ohm max load, not for use with externally powered circuit
For sodium, conditioned pH, temperature
four powered 0/4-20 mA,
Power Supply (AC/DC)
100 V – 240 V
Analog Output Scaling
Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging
Flow Rate
40 mL/min – 60 mL/min
Measurement Parameter
Sodium
Electrode Conditioning
Manual
Operating Range (Temp.)
5 °C – 50 °C
Relay Contacts
3 A resistive freely assignable to set-points for sodium, pH, temperature
Sodium Calibration
Manual 3-point known addition
manual 1- or 2-point
Operating Range
0.01 ppb – 100,000 ppb
Analog Output Accuracy
±0.05 mA
EnclosureType
Panel
Outputs
4 Analog
Built-in sequencer
No

Documentation

Accessories

Consumables

Software

More Information