pipette software

PipetteX

Simple Pipette Management for All Pipette Brands

Call for Quote

pipette software
pipette asset management software
PipetteX is 21 CFR Part 11 Compliant

pipette asset management
pipette asset management

Products and Specs

First-Time and Renewal Keys for PipetteX Pipette Asset Management

\
 
Products and Specs
Filter:
Set filter
Clear All
 
Material No.: 30475911
See details
Material No.: 30475913
See details
Material No.: 30475915
See details
Material No.: 30587187
See details
Material No.: 30478258
See details
Material No.: 30587190
See details
Material No.: 30583206
See details
Material No.: 30583207
See details
Material No.: 30590989
See details
Material No.: 30604679
See details
Material No.: 30604682
See details
Material No.: 30478260
See details
Material No.: 30478262
See details
Comparison

Documentation

Documents

PipetteX Reference Manual
Along with the SmartStand, PipetteX is meant to simplify the management of all your pipettes. The software is designed to work with both METTLER TOLED...
PipetteX Data Sheet
Spend a lot less time tracking and managing pipette calibration, and have more complete and accurate records than you ever imagined possible. With so...
PipetteX Installation Instructions
This document is intended for users who are responsible for running system administration operations. We recommend that only persons with the necessar...
pipettex asset management software
You will find relevant topics to setting up the software, knowledge papers on improving your lab setup, video manuals, and much more. Click on any of...
PipetteX Product Brochure
Download the PipetteX pipette asset management product brochure. With Rainin PipetteX, SmartStand, and SmartCheck, you have a powerful pipette tracki...
Pipette Method Card - Operating Instructions
Use the Pipette Method Card to develop your skills and get step by step instructions.
SmartCheck and PipetteX Datasheet
Testing pipette accuracy used to be difficult, requiring a balance and time-consuming calculations. Now, thanks to SmartCheck and PipetteX, any resear...
optimal quality management for pipettes
This white paper is a practical guide to the proper use and regular maintenance of pipettes which are key to achieving reliable pipetting results.

Services

+34 900 922 550
Call Service
Uptime
Support & Repair
Performance
Maintenance & Optimization
Compliance
Calibration & Quality
Expertise
Training & Consulting

FAQ

How does good pipette management contribute to reproducible data?

Reproducible data is the standard by which scientific results are measured. Outcomes must be repeatable to provide a foundation for future research.

Well-maintained and calibrated instruments are critical to achieving reproducible results. With PipetteX™ pipette asset management, METTLER TOLEDO offers a solution to manage your pipettes in a simple, efficient and visual way.

Try PipetteX pipette asset management software now!

 


What is pipette asset management?

Pipette asset management applies to the practices involved with managing valuable assets to pipettes. A pipette asset management system simplifies and largely automates the task of managing service, calibration and recordkeeping.

Pipette asset management includes:

  • Pipette identification (user(s), lab(s), serial number, manufacturer)
  • Usage monitoring (daily use, age, etc.)
  • Location monitoring
  • Service scheduling, including alerts to both managers and end users
  • Service history and data
  • Routine pipette-check reminders, with saved, customizable methods to guide end users
  • Storage and retrieval of calibration certificates

A comprehensive pipette asset management system supports pipette performance and provides proof of regulatory compliance anytime.

 

What is PipetteX pipette asset management?

Together with SmartStand, PipetteX™ offers a powerful pipette tracking and calibration management system. Using the RFID chip embedded in every Rainin XLS-brand pipette, PipetteX tracks every pipette’s usage, performance, location and service data automatically.

How does PipetteX work?

PipetteX™ offers a simple, unified system for tracking and managing pipettes:

  1. Place any Rainin XLS-brand pipette on a SmartStand to instantly see the pipette’s calibration status and service details right at the bench.
  2. SmartStands connect to PipetteX via Bluetooth wireless technology or USB to automatically transfer pipette serial numbers, service and other data to the PipetteX database.
  3. PipetteX maintains a complete history of your entire pipette inventory including calibration certificates and verification reports.

This makes it easy to track the status, location, calibration and service schedule for any pipette.

 

Can PipetteX help manage my pipette calibration certificates?

When Rainin pipette service is provided by METTLER TOLEDO, CalibrateOnSite or CalibrateLab, electronic certificates can be transmitted and stored automatically in PipetteX™. Full service history is also provided, including any spare parts replaced or repairs made.

 

How can I test the performance of my pipettes? 

SmartCheck allows you to check the performance of pipettes in your lab between calibrations. Tools from Rainin and METTLER TOLEDO expedite the process, and offer automatically calculated results within minutes that can be tracked for compliance. See the video guide for more information.

 

 

Can I import my current pipette data into PipetteX if I use Excel or a Laboratory Information Management System (LIMS)?

Yes. PipetteX™ features an import and export functionality allowing you to seamlessly transfer data in .xls, .xlsx and .csv format.

 

Do I need Rainin pipettes to use PipetteX?

PipetteX™ is a great way to manage pipettes of any brand, or even a mixed inventory of brands.

When serviced by Rainin, METTLER TOLEDO or Calibrate, the service data for any brand of pipette is automatically updated in PipetteX, and electronic certificates are available to print or review.

Managing pipettes with PipetteX is even easier with Rainin XLS pipettes because pipette data (e.g., age, serial number) are stored on each pipette's RFID chip. PipetteX automatically updates a pipette's usage, location and service data when it is placed on a Rainin SmartStand. SmartStand displays service and compliance status right at the bench, so users always know a pipette's calibration status.

 

How do I search for a pipette?

Type a search term, such as user, asset ID, channels, volume, manufacturer, serial number, etc., into the top cell of any PipetteX™ column. As you type, results in that column will filter to the best-matching result.

When you see information matching the pipette you're looking for, scroll horizontally to the "Last Seen" column to identify the SmartStand on which this pipette was most recently placed.

 

What is lifecycle status?

The lifecycle status chart shows you the age of your pipettes. Along with usage, lifecycle status is an important signal in assessing when a pipette should be replaced.

 

Can PipetteX be used to manage pipettes across multiple labs, potentially at different sites?

Yes. PipetteX™ works with multiple SmartStands in diverse locations to deliver a single point of control.

 

Can I sort pipettes by lab?

Yes. PipetteX™ offers many ways to "slice and dice" your pipette inventory and data.

 

How can I quickly see if my pipette inventory is in good shape?

If almost everything on your PipetteX home screen is green, it means pipettes are in service and their calibration is up to date: All good. Yellow indicates that service dates are approaching or that a pipette has not been on a SmartStand for an extended period. Red indicates pipettes that are past due for service and/or calibration.

 

What is the quickest way to sort my inventory for past-due pipettes?

In the lower left of the PipetteX™ home screen, click the red portion of the Calibration service status chart. If nothing is red, you don't have any past-due pipettes.

 

Can I batch edit pipette data?

Yes. In PipetteX™, it's easy to select multiple pipettes based on shared criteria and make batch changes as needed.

 

Can PipetteX alert users when a pipette is due for service?

Yes. You can set up automated email reminders to both managers and end users in advance of pipette service due dates.

 

Does PipetteX create pick lists?

Yes. It's easy to filter for pipettes that need service during the same period and generate a list.

 

Does PipetteX have an audit trail functionality?

Yes, you can activate an audit trail if required. The audit trail can be reviewed and signed-off on electronically.

 

Can I capture results from my SmartCheck?

Yes, PipetteX™ can capture all measurement results from a SmartCheck as well as set individual tolerances per pipettes (rather than the 5% default). Please read the manual to see what the test reports look like.

 

Can I export all the data from PipetteX?

Yes, you can export all data from PipetteX™ in csv, xml or xls format. All calibration certificates and routine test reports can be downloaded automatically with structured file names for easy exporting to other applications.

 

Can I integrate PipetteX in my ERP or LIMS?

Yes, PipetteX™ can integrate through a file exchange. All files are structured files that can be crawled easily.

 

I don't have a PC in all my labs. Can SmartCheck be operated without it?

Yes, SmartCheck can be connected through a gateway with the PipetteX™ server. This allows a PC-free lab to use the SmartCheck still and automatically capture measurement data. 

 

Does PipetteX support 21 CFR Part 11 Compliance?

Yes, PipetteX™ supports 21 CFR Part 11 compliance as it offers several features such as electronic signatures, audit trails, user management, etc. Also, validation handbooks are offered. Check with your local country organization whether validation services are offered too.